GHEX19 Series
Spring-Loaded DC-Output Explosion-Proof LVDT
Features
- range: 6~100mm
- Explosion-proof grade: Ex ia ⅡC T6 Ga
- 24V DC-operated
- 4-20mA DC current output
- Linearity: ≤±0.25% FS, (±0.1% optional)
- Aviation connector
- IP-68 protection rating
Applications
- Hazardous environment
- Oil-gas field
- LNG
- Valve position measurement
- Material Testing Machine
- Automated production line
The GHEX19 series intrinsically safe explosion-proof spring-loaded DC output LVDT displacement sensor is widely used in various position measurement applications. The sensor features a stainless steel housing and achieves an IP-68 protection rating, capable of withstanding harsh environmental conditions.
The sensor consists of a spring-loaded shaft that operates within a precision sleeve bearing and is connected to the LVDT core. Repeatability can reach 0.6 microns or better. The spring-loaded probe extends and retracts freely, and depending on the application environment, the spring force can be adjusted from 50g to 500g (customized).
The sensor incorporates built-in electronics, retaining the technical advantages of AC LVDTs (such as frictionless operation and high dynamic response) while offering ease of use and simple construction. The DC output facilitates integration with PLCs, digital indicators, A/D converters, computer-based data processors, and QC data collection systems.
The GHEX19 series LVDT sensors cover a measuring range of 6mm to 100mm. They feature high resolution, excellent repeatability, and low hysteresis.
Explosion-Proof Statement: The explosion-proof marking of this product is Ex ia IIC T6 Ga. The effective ambient temperature range for intrinsic safety is -20°C to +60°C. Under the maximum ambient temperature of +85°C and specified fault conditions, the maximum temperature of any surface of the equipment shall not exceed 85°C. It is suitable for Zone 0, Group IIC explosive gas atmospheres. Beyond the above ambient temperature range, the explosion-proof performance is not guaranteed. This explosion-proof temperature limit refers to the air ambient temperature where the sensor electronics body is located; the probe rod may contact higher-temperature measured objects, but thermal insulation and heat dissipation measures must be taken to ensure the electronics body temperature does not exceed the limit.
Electrical Specifications
| Parameters | Description |
| Input Voltage: | 10-28V DC, 24V (rms) |
| Output: | 4-20mA DC |
| Linearity Error: | <±0.25% of FSO,<0.1%(optional) |
| Repeatability Error: | <0.6um |
| Explosion-proof Rating | Ex ia ⅡC T6 Ga |
| Operating Temperature | -20℃ to +60℃ |
| Thermal Coefficient | -0.02%/°C (nominal) |
Dimensions
| Parameters | Range code ⇒ | 006 | 013 | 025 | 050 | 100 |
| Range | mm | 6 | 13 | 25 | 50 | 100 |
| Body length "A" | mm | 176.7 | 191.7 | 308 | 373.7 | 579.7 |
| Body length "B" | mm | 148 | 163 | 270 | 310 | 459 |
| Body length "C" | mm | 108 | 123 | 190 | 230 | 320 |
| Pretravel | mm | 3.3 | 4.5 | 1 | 0.85 | 2 |
Wiring Connection
Ordering Guide
Specialized Accessories
| Part Number | Part Name | Model | descriptions | Configuration |
| 0356-C4-0001 | Connectors & Cables | C-4-2M | PT06A+ RT cable, 4 cores, green jacket, 2 meters | default (setting) |
| 0356-C4-0002 | Connectors & Cables | C-4-5M | PT06A+ PUR cable, 4 cores, green jacket, 5meters | |
| 0356-C4-0003 | Connectors & Cables | C-4-10M | PT06A+ PUR cable, 4 cores, green jacket, 10meters | |
| 20069388-4 | Connectors | PT06A-10-6S(SR) | Connector only, without cables | |
| 0355-001 | Mounting Block | MTD-19 | For O.D. 19mm LVDT installation |